7100 Vertical Rod type (7100V & F7100V)


Specifications 

Material :
push ber – steel pressed or stainless steel pressed
Head Cover – Steel pressed or stainless steel pressed 
Spring – Stainless steel

Latch Bolt :
5/8′ throw, stainless steel

Dead Latch bolt :
5/8″, steel

Strike :
for 5/8″ stop. 

Projection :
2-1/2″ maximum, 1-7/8″ pressed

Reversible :
Non-handed, reversible for all functions and trims

For Door :
1-3/4″ thick of wood or metal door. specify thickness if other than 1-3/4″

door width :
3′ standard for door width of 2′-8″ to 3′-0″,4′ standard for door width of 3′-8″ to 4′-0″

Stile :
4-1/4″ minimum. 

Top and bottom rod length for 7′ door :
Top rod 35-1/3″, bottom rod 31-1/4″

Top and bottom rod length for 8′ door :
Top rod 47-2/3″, bottom rod 31-1/4″

Mounting height :
40-5/16″ from CL to finished floor recommended

Mounting :
Furnished standard with sheet metal & machine screws or SNB as option

Cylinders :
For trim, knob, lever & thumb-piece type “schlage C” key way

Dogging :
1/4 turn, hex key dogging on non-fire labeled device

UL Listed :
For “panic hardware” and “UL”. labeled (3 hours) fire exit hardware. (testing)

Ansi standard:
A156.3 grade 1

Operation :
inside by slight pressure on any point of the push bar all time

Head cover : 
Big 8-1/2″ x 2-3/4″ x 2-1/2″ (216mm x 68.3mm x 62mm) &
Small 6-1/3″ x 2-3/4″ x 2-1/2″ (160mm x 68.2mm x 60mm)

Standard Finishes : 
US26, US26D, US32D (or other finishes upon request & discussion)

Contact Now

Description

7100 Vertical Rod type (7100V & F7100V)

PRODUCT INFORMATION


Specifications 

Material :
push ber – steel pressed or stainless steel pressed
Head Cover – Steel pressed or stainless steel pressed 
Spring – Stainless steel

Latch Bolt :
5/8′ throw, stainless steel

Dead Latch bolt :
5/8″, steel

Strike :
for 5/8″ stop. 

Projection :
2-1/2″ maximum, 1-7/8″ pressed

Reversible :
Non-handed, reversible for all functions and trims

For Door :
1-3/4″ thick of wood or metal door. specify thickness if other than 1-3/4″

door width :
3′ standard for door width of 2′-8″ to 3′-0″,4′ standard for door width of 3′-8″ to 4′-0″

Stile :
4-1/4″ minimum. 

Top and bottom rod length for 7′ door :
Top rod 35-1/3″, bottom rod 31-1/4″

Top and bottom rod length for 8′ door :
Top rod 47-2/3″, bottom rod 31-1/4″

Mounting height :
40-5/16″ from CL to finished floor recommended

Mounting :
Furnished standard with sheet metal & machine screws or SNB as option

Cylinders :
For trim, knob, lever & thumb-piece type “schlage C” key way

Dogging :
1/4 turn, hex key dogging on non-fire labeled device

UL Listed :
For “panic hardware” and “UL”. labeled (3 hours) fire exit hardware. (testing)

Ansi standard:
A156.3 grade 1

Operation :
inside by slight pressure on any point of the push bar all time

Head cover : 
Big 8-1/2″ x 2-3/4″ x 2-1/2″ (216mm x 68.3mm x 62mm) &
Small 6-1/3″ x 2-3/4″ x 2-1/2″ (160mm x 68.2mm x 60mm)

Standard Finishes : 
US26, US26D, US32D (or other finishes upon request & discussion)

DRAWINGS & DIMENSIONS

MOUNTING POSITION

MODEL